Skip to main content

Types of Purified Water Systems in Pharmaceuticals

 
Types of Purified Water Systems in Pharmaceuticals

Purified water is prepared with using different purification methods like ion exchange, reverse osmosis and distillation. These purification methods are discussed here.

One of the most pronounced ingredients in any pharmaceutical engineering is water. Water serves as a solvent and ingredient for formulation in many pharmaceutical procedures. Special care and attention must, therefore, be taken to ensure that the water used, meets the standard quality for purified water. Water is purified to remove impurities and prevent microbes which might cause contamination of products.

For water to be rendered purified, it is passed through different types of induatrial water purification systems including distillation, filtration, reverse osmosis and ion exchange. However, other suitable procedures such as ultrafiltration can also be used. Purified water is used in pharmaceutical applications such as preparation of heavy pharmaceutical products and cleaning of certain equipment and systems.

The primary source of purified water is drinking water. As such, the feed water must be protected from microbial proliferation. When considering any type of industrial water filtration systems, it is essential to consider periodic sanitization because microbes may thrive during production, storage, and distribution. One of the general principles which apply to any type of purified water systems in pharmaceuticals entails prevention of any microbial and physical re-contamination. The justification for use of purified water lies on the premise that purified water contains less solid impurities, estimated to be about one percent, than ordinary feed water.

There are three often used different types of industrial water filtration systems in pharmaceuticals which will be discussed including; ion exchange, reverse osmosis (RO) and distillation.

1. Ion exchange is one of the most desirable types of purified water treatments. It involves separation of water-soluble undesirable ions and exchanging those ions with desirable ones. Therefore, this water treatment technology focuses on altering the ionic composition in a desirable direction. Due to its ease of operation, minimal maintenance, the ion exchange method is mostly preferred in pharmacies as a type of purified water system.

2. Reverse osmosis (RO) entails applying pressure to the concentrated solution in an osmosis process, thereby disrupting the natural osmotic flow.

As a result, water starts flowing from the more concentrated to the less concentrated solution. It is strongly advised that RO systems being utilized for pharmaceutical manufacturing be designed for control of bacteria. RO units are often susceptible to microbial fouling and must be cleaned thoroughly and regularly.

3. Distillation is another widely used type of purified water system in pharmaceutical practice is distillation. As a general principle, the first ten to twenty percent distillate must be discarded because the feed water contains innumerable volatile substances. The same case applies to the last wenty percent to prevent excessive dryness which would result in solid impurities contaminating the previous distillate. Heat is used to boil the liquid mixture containing volatile components. Later on, condensation is used to recover the vapor.

Water purification for use in pharmaceutical procedures is aimed at achieving a certain level of chemical purity in order to prevent contamination of pharmaceutical products. Through the various types of purified water systems including; ion exchange, distillation and reverse osmosis, pharmacies are able to remove solid impurities from ordinary drinking water.

Comments

Popular posts from this blog

Checklist for Audit in Sterile Area

Checklist for Audit in Sterile Area Checklist to verify the sterile manufacturing area before the audit. 1. Is there any SOP giving details for activity/ movement in the sterile area. 2. Verify the suitability of system for sanitization of hands. 3. Is there the SOP on entry-exit; gowning and de-gowning into the critical area available? 4. Verify the availability of following records:  Air pressure differential  Particulate monitoring  Temperature  Humidity  Microbiological monitoring by settle plate 5. Are these records available and maintained as per SOPs? 6. Check the above mentioned individual records. Are the entries within specifications mentioned in SOP/ MTPs. 7. Is the controlled copy of MTP pertaining to monitoring by settle plate available to plant person? 8. Are the location for settle plates identified and the chart/ layout available with plant? 9. Are the following areas monitored for parameters mentioned in step 4:  Air-lock to the critical ar...

Aseptic Filling Process (Media Fill) Validation Protocol in Sterile Pharmaceuticals

Aseptic Filling Process (Media Fill) Validation Protocol in Sterile Pharmaceuticals Validation of sterile manufacturing process by media fill validation test as per PICS guidelines for aseptic validation or aseptic process simulation. 1.0 OBJECTIVE 1.1 To define procedures for validating and maintaining the validation of all aseptic filling processes and qualification of the quality of the product by system/facility/equipment. 2.0 SCOPE 2.1 This procedure applies to all aseptically filled sterile products intended for human use. 3.0 RESPONSIBILITY 3.1 The Validation personnel coordinate the aseptic filling validation program and write the sterile media aseptic filling processes reports. 3.2 Manufacturing personnel the sterile media aseptic filling processes and performs the sterile media fills. 3.3 QA personnel perform the sampling and assist with the IPQA monitoring required for each sterile media fill. 3.4 QC personnel to perform the testing and assist with the monitoring required fo...

Blow Fill Seal (BFS) and Form Fill Seal (FFS) Technology in Sterile Manufacturing

Blow Fill Seal (BFS) and Form Fill Seal (FFS) Technology in Sterile Manufacturing Know about sterile pharmaceutical production using Blow Fill Seal (BFS) and Form Fill Seal (FFS) technology. Both of these techniques are used to manufacture  sterile pharmaceutical products   as parenteral (LVP & SVP), infusions, ophthalmic and inhalation products. These are automated techniques to prepare sterile products. The basic concept of the  FFS   and BFS is to reduce the  contamination   by forming the container, filling and sealing in a closed sterile chamber of the machine. There is no personnel intervention to reduce the chances of the contamination during the manufacturing of sterile products. It gives more production at very low operational cost with the high assurance of  sterility . Blow fill seal technology is widely used and accepted by the various pharmaceutical regulatory authorities as US-FDA and MHRA. The system is being used for over 30 years a...