Skip to main content

Media Fill Test for Sterile API Manufacturing Process

Media Fill Test for Sterile API Manufacturing Process

Know about the process simulation test for the active pharmaceutical ingredient (API) manufacturing process.

Media fill test is done to verify the sterility of the sterile manufacturing process. Media fill validation for sterile API is different from the sterile formulation media fill.

There are different processes in the sterile API manufacturing as filtration, crystallization, drying, milling etc. These all are different from the sterile formulation process where the sterile material is filled in sterile containers in aseptic conditions. Lactose powder is used in the process simulation.

The whole media fill process is carried out in two phases

1) Wet Phase 

2) Dry phase

1) Wet Phase: 

Non-sterile lactose powder is used in the wet phase. Wet phase simulates the liquid processing steps of the manufacturing process i.e. aseptic filtration of lactose solution from controlled area reactor to crystallizer of the aseptic zone. The non-sterile lactose solution is sterilized by aseptic filtration, through filtration train of sterilizing-grade filters.

A solution of non-sterilized lactose powder is prepared with water for injection (WFI) and filtered through the plate & frame filter and lactose solution is transferred to the crystallizer. Water is added as a solvent in the crystallizer through the solvent transfer line. Now complete solution from the crystallizer is filtered through a pre-sterilized 0.45µm filter of 142 mm diameter, under air pressure of NMT 1.0 Kg under aseptic conditions.

After the completion of filtration, the filter is aseptically removed and placed onto pre-incubated 200 mm diameter SCDA media plates. These SCDA media plates are immediately transferred to the microbiology laboratory and incubated at 22.5 + 2.5°C for 7 days and 32.5 + 2.5°C for next 7 days and count the colony forming units (cfu).

2) Dry Phase: 

Pre-sterilized lactose powder is used in the dry phase of the process simulation test. This phase simulates the powder processing steps of the manufacturing process i.e. from Nutsche Filter, Vacuum Tray Drying, Powder Filling, Milling, Blending and filling in a sterilized aluminum canister.

Pre-sterilized lactose powder is charged in Nutsche filters and kept on hold for a time period of 6 hours, to simulate the slurry filtration time during normal production batches. Nutsche filter is transferred to VTD room. Lactose is transferred to VTD trays by using pre-sterilized scoops. The total quantity is distributed in VTD trays. On completion of the contact time of Lactose in VTD, the VTD trays are unloaded in pre-sterilized SS Bins.

Lactose is passed through the Multi-mill and the milled lactose powder is collected in sterilized SS Bins. Lactose powder is further charged in the blender and blending is done for 2 hours to simulate the longest blending time. Lactose is unloaded in depyrogenated aluminum canisters to simulate the filling operations. These canisters are sealed and manually rotated & shaken so that lactose can get in contact with the internal surface of the canister as well as the closure.

Now sterile lactose (5 kg capacity canisters) is charged aseptically in a blender. Blended lactose is filled in aluminum canisters to simulate blend batches. As a parallel activity, the critical area crystallizer is charged with 1100 liters of WFI through 1.2 µm, 0.2 µm & 0.2 µm filters, for dissolving lactose (less than 10 % Lactose solution).

Lactose from the filled aluminum canister is charged aseptically into the crystallizer through the manhole and agitated to dissolve lactose.

A filtration assembly, with a membrane filter holder, is attached to the bottom line of crystallizer and the complete lactose solution is aseptically filtered through pre-sterilized 0.45 µm filter of 142 mm diameter, under air pressure of NMT 1.0 Kg.

After the completion of filtration, the filter is placed on 200 mm diameter, pre-incubated SCDA media plates. These SCDA media plates are immediately transferred to the microbiology laboratory and incubated at 22.5 + 2.5°C for 7 days and 32.5 + 2.5°C for next 7 days and count the colony forming units (cfu).

Samples can be collected for sterility at the completion of various stages as at the time of unloading of VTD, multi mill and blending.

Note: Time for each activity must be similar to the actual manufacturing process for the product.

Acceptance Criteria: Contamination in one unit in 10,000 units is acceptable for media fill; it means 0.01% contamination is acceptable. In bulk manufacturing where sterile API is filled in large quantities in containers; how to calculate the percentage of units?

Therefore, in API media fill the acceptance criterion is different from the formulation. Here the whole batch is converted into the number of units. For example: Ceftriaxone Sodium batch of 160.00 Kg has injectable formulation units of 250 mg, 500 mg and 1 g available in the market, then 100.00 Kg batch is to be converted into 1gm (highest strength) vial units i.e. number of vials = 160,000gm / 1gm/vial = 1,60,000 units.

a) Now, suppose 10 CFUs (colony forming units) are observed after incubation period is over, the contamination rate calculation shall be (10 units/1,60,000 units) x 100 = 0.00625 %. Since actual contamination of 0.00625% is less than the limit of 0.01%, therefore this contamination rate would be acceptable.

b)  Suppose 16 CFUs (colony forming units) are observed after incubation period is over, the contamination rate calculation shall be (16 units/1,60,000 units) x 100 = 0.01 %. Therefore this contamination rate shall not be acceptable.

Comments

Popular posts from this blog

Checklist for Audit in Sterile Area

Checklist for Audit in Sterile Area Checklist to verify the sterile manufacturing area before the audit. 1. Is there any SOP giving details for activity/ movement in the sterile area. 2. Verify the suitability of system for sanitization of hands. 3. Is there the SOP on entry-exit; gowning and de-gowning into the critical area available? 4. Verify the availability of following records:  Air pressure differential  Particulate monitoring  Temperature  Humidity  Microbiological monitoring by settle plate 5. Are these records available and maintained as per SOPs? 6. Check the above mentioned individual records. Are the entries within specifications mentioned in SOP/ MTPs. 7. Is the controlled copy of MTP pertaining to monitoring by settle plate available to plant person? 8. Are the location for settle plates identified and the chart/ layout available with plant? 9. Are the following areas monitored for parameters mentioned in step 4:  Air-lock to the critical ar...

Aseptic Filling Process (Media Fill) Validation Protocol in Sterile Pharmaceuticals

Aseptic Filling Process (Media Fill) Validation Protocol in Sterile Pharmaceuticals Validation of sterile manufacturing process by media fill validation test as per PICS guidelines for aseptic validation or aseptic process simulation. 1.0 OBJECTIVE 1.1 To define procedures for validating and maintaining the validation of all aseptic filling processes and qualification of the quality of the product by system/facility/equipment. 2.0 SCOPE 2.1 This procedure applies to all aseptically filled sterile products intended for human use. 3.0 RESPONSIBILITY 3.1 The Validation personnel coordinate the aseptic filling validation program and write the sterile media aseptic filling processes reports. 3.2 Manufacturing personnel the sterile media aseptic filling processes and performs the sterile media fills. 3.3 QA personnel perform the sampling and assist with the IPQA monitoring required for each sterile media fill. 3.4 QC personnel to perform the testing and assist with the monitoring required fo...

MSDS (Material Safety Data Sheet)

MSDS   What Is an MSDS? An MSDS (Material Safety Data Sheet) is a document that provides detailed information about a chemical substance, including its hazards, safe handling procedures, storage requirements, and emergency measures. Today, MSDS is more commonly called SDS (Safety Data Sheet) under the Globally Harmonized System (GHS). Why MSDS / SDS Is Important Protect workers and employees Ensure safe handling and storage of chemicals Prevent accidents and injuries Provide emergency response information Comply with workplace safety regulations.  MSDS (Material Safety Data Sheet)  International safety standards.  GHS – Globally Harmonized System Full form: Globally Harmonized System of Classification and Labelling of Chemicals Develop by United Nations (UN).  OSHA (USA) – Hazard Communication Standard (HCS) Factories Act & Chemical Rules (India) Factories Act, 1948 Manufacture, Storage and Import of Hazardous Chemical Rules, 1989 REACH (Europe) REACH Regula...

Steps for HPLC Method Development

Steps for HPLC Method Development Know about the different steps of the HPLC analytical method development in pharmaceutical analysis. Analytical method development is considered as a critical process in pharmaceuticals. Availability of the different types of columns, operating  parameters, mobile phase composition, diluent and pH values make it critical to develop an analytical method. A good analytical method should be  simple, used column, mobile phase and buffer should be common. It can be done easily step by step. Following are the common HPLC method development steps. 1. Selection of HPLC Analytical Method 2. Selection of Chromatographic Conditions 3. Parameter Optimization 1. Selection of HPLC Analytical Method: First of all consult the literature that is available on the product. It will help you to understand the nature of  the product that will help to select the different parameters. A. Sample Preparation: Select method to prepare the sample according to its ...

Blow Fill Seal (BFS) and Form Fill Seal (FFS) Technology in Sterile Manufacturing

Blow Fill Seal (BFS) and Form Fill Seal (FFS) Technology in Sterile Manufacturing Know about sterile pharmaceutical production using Blow Fill Seal (BFS) and Form Fill Seal (FFS) technology. Both of these techniques are used to manufacture  sterile pharmaceutical products   as parenteral (LVP & SVP), infusions, ophthalmic and inhalation products. These are automated techniques to prepare sterile products. The basic concept of the  FFS   and BFS is to reduce the  contamination   by forming the container, filling and sealing in a closed sterile chamber of the machine. There is no personnel intervention to reduce the chances of the contamination during the manufacturing of sterile products. It gives more production at very low operational cost with the high assurance of  sterility . Blow fill seal technology is widely used and accepted by the various pharmaceutical regulatory authorities as US-FDA and MHRA. The system is being used for over 30 years a...