Skip to main content

HPLC Column Void Volume

HPLC Column Void Volume
Void volume in High Performance Liquid Chromatography system analysis plays an important role in accuracy of the analysis. void volume affects the resolution of the HPLC system.

High-Performance Liquid Chromatography system is a test used mainly in analytical chemistry for identification, quantitative and control of related substances in chemical mixtures. The technique depends mainly on the uniqueness of the molecular weights and the polarities of elements.
Compounded mixtures are passed through the HPLC column and depending on the unique features stated above; they are separated before they can leave the HPLC column.

The HPLC set up is composed of two main parts, a mobile phase and a stationary phase. The stationary phase is a solid packed in a column, usually consisting of a silica gel while the mobile phase is a liquid solvent mixture. The mobile phase is pumped up the column where separation takes place followed by detection.

There are several volumes in the column such as the column volume, bed volume, elution volume, retention volume and void volume to name a few.

The HPLC column void volume denoted Vm or V0 is in simple terms the volume of the mobile phase in the column. It is the part of a fraction that when added to the volume of the stationary phase makes up a whole fraction or 100% volume.

The HPLC column void volume is considered in the presence of the stationary phase particles, meaning that if there is no stationary phase, then the void volume cannot be calculated. The HPLC column void volume is also roughly the minimum amount of the solvent that has to be pumped through the column before any sample that is introduced by injection can be detected.

Determination of the HPLC column void volume is mainly approximate. If unknown, the volume is determined by the injection of an unretained standard that usually has minimal retention in any given phase. This means that its role is almost inert relative to the components of the mobile phase. A product of this unretained standard and the flow rate of the system gives the column void volume of that particular system. It should be noted that the packed volume of the column and the flow rate can also be utilized to the same effect in the calculation of the volume.

To determine the various volumes in High-Performance Liquid Chromatography system, the dimensions of the capillary column that holds the mobile phase are mostly used, i.e., its length and radius.

The general formula for determination of the HPLC column void volume is given by:
Vm = F x to

Where;
Vm is the void volume
F is the flow rate in Millilitres per minute
to is the column dead time
Alternatively, the dimensions of the column can be used as well as the percentage of the void volume as a factor of the total volume. Using this
method, the formula becomes;

Vm = y x π x (i.d/2)2 x L

where;
Vm is the void volume
y is the fraction of the void volume as a function of the total volume usually about 70%
i.d is the internal diameter of the column in centimeters
L is the length of the column in centimeters.

HPLC column void volume and the flow rate are useful in the calculation of a value known as the column void time, otherwise known as to. Knowing this value is helpful in the determination of other critical chromatographic values such as the resolution and the separation factor of a compound.

Comments

Popular posts from this blog

Checklist for Audit in Sterile Area

Checklist for Audit in Sterile Area Checklist to verify the sterile manufacturing area before the audit. 1. Is there any SOP giving details for activity/ movement in the sterile area. 2. Verify the suitability of system for sanitization of hands. 3. Is there the SOP on entry-exit; gowning and de-gowning into the critical area available? 4. Verify the availability of following records:  Air pressure differential  Particulate monitoring  Temperature  Humidity  Microbiological monitoring by settle plate 5. Are these records available and maintained as per SOPs? 6. Check the above mentioned individual records. Are the entries within specifications mentioned in SOP/ MTPs. 7. Is the controlled copy of MTP pertaining to monitoring by settle plate available to plant person? 8. Are the location for settle plates identified and the chart/ layout available with plant? 9. Are the following areas monitored for parameters mentioned in step 4:  Air-lock to the critical ar...

Aseptic Filling Process (Media Fill) Validation Protocol in Sterile Pharmaceuticals

Aseptic Filling Process (Media Fill) Validation Protocol in Sterile Pharmaceuticals Validation of sterile manufacturing process by media fill validation test as per PICS guidelines for aseptic validation or aseptic process simulation. 1.0 OBJECTIVE 1.1 To define procedures for validating and maintaining the validation of all aseptic filling processes and qualification of the quality of the product by system/facility/equipment. 2.0 SCOPE 2.1 This procedure applies to all aseptically filled sterile products intended for human use. 3.0 RESPONSIBILITY 3.1 The Validation personnel coordinate the aseptic filling validation program and write the sterile media aseptic filling processes reports. 3.2 Manufacturing personnel the sterile media aseptic filling processes and performs the sterile media fills. 3.3 QA personnel perform the sampling and assist with the IPQA monitoring required for each sterile media fill. 3.4 QC personnel to perform the testing and assist with the monitoring required fo...

MSDS (Material Safety Data Sheet)

MSDS   What Is an MSDS? An MSDS (Material Safety Data Sheet) is a document that provides detailed information about a chemical substance, including its hazards, safe handling procedures, storage requirements, and emergency measures. Today, MSDS is more commonly called SDS (Safety Data Sheet) under the Globally Harmonized System (GHS). Why MSDS / SDS Is Important Protect workers and employees Ensure safe handling and storage of chemicals Prevent accidents and injuries Provide emergency response information Comply with workplace safety regulations.  MSDS (Material Safety Data Sheet)  International safety standards.  GHS – Globally Harmonized System Full form: Globally Harmonized System of Classification and Labelling of Chemicals Develop by United Nations (UN).  OSHA (USA) – Hazard Communication Standard (HCS) Factories Act & Chemical Rules (India) Factories Act, 1948 Manufacture, Storage and Import of Hazardous Chemical Rules, 1989 REACH (Europe) REACH Regula...

Steps for HPLC Method Development

Steps for HPLC Method Development Know about the different steps of the HPLC analytical method development in pharmaceutical analysis. Analytical method development is considered as a critical process in pharmaceuticals. Availability of the different types of columns, operating  parameters, mobile phase composition, diluent and pH values make it critical to develop an analytical method. A good analytical method should be  simple, used column, mobile phase and buffer should be common. It can be done easily step by step. Following are the common HPLC method development steps. 1. Selection of HPLC Analytical Method 2. Selection of Chromatographic Conditions 3. Parameter Optimization 1. Selection of HPLC Analytical Method: First of all consult the literature that is available on the product. It will help you to understand the nature of  the product that will help to select the different parameters. A. Sample Preparation: Select method to prepare the sample according to its ...

Blow Fill Seal (BFS) and Form Fill Seal (FFS) Technology in Sterile Manufacturing

Blow Fill Seal (BFS) and Form Fill Seal (FFS) Technology in Sterile Manufacturing Know about sterile pharmaceutical production using Blow Fill Seal (BFS) and Form Fill Seal (FFS) technology. Both of these techniques are used to manufacture  sterile pharmaceutical products   as parenteral (LVP & SVP), infusions, ophthalmic and inhalation products. These are automated techniques to prepare sterile products. The basic concept of the  FFS   and BFS is to reduce the  contamination   by forming the container, filling and sealing in a closed sterile chamber of the machine. There is no personnel intervention to reduce the chances of the contamination during the manufacturing of sterile products. It gives more production at very low operational cost with the high assurance of  sterility . Blow fill seal technology is widely used and accepted by the various pharmaceutical regulatory authorities as US-FDA and MHRA. The system is being used for over 30 years a...