Steps for HPLC Method Development

Steps for HPLC Method Development

Know about the different steps of the HPLC analytical method development in pharmaceutical analysis.

Analytical method development is considered as a critical process in pharmaceuticals. Availability of the different types of columns, operating 

parameters, mobile phase composition, diluent and pH values make it critical to develop an analytical method. A good analytical method should be simple, used column, mobile phase and buffer should be common. It can be done easily step by step.

Following are the common HPLC method development steps.

1. Selection of HPLC Analytical Method

2. Selection of Chromatographic Conditions

3. Parameter Optimization

1. Selection of HPLC Analytical Method: First of all consult the literature that is available on the product. It will help you to understand the nature of the product that will help to select the different parameters.

A. Sample Preparation: Select method to prepare the sample according to its solubility, filtration requirements, extraction requirements or other special requirements to make a clear solution of HPLC analysis.

B. Chromatography: Reverse phase chromatography is used for most of the samples but when acidic or basic molecules are present in the sample then reverse phase ion suppression (for weak acid or base) or reverse phase ion pairing (for strong acid or base) should be used. The stationary phase should be C18 bonded. Normal phase is used for low or medium polarity analyte especially when it is required to separate the product isomers. Choose cyano bonded phase for normal phase separations. Ion exchange chromatography is best to use for inorganic anion or cation analysis. If analyte has higher molecular weight than size exclusion chromatography is the best to use.

C. Gradient/Isotonic HPLC: Gradient HPLC is helpful in the analysis of complex samples having a number of components. It will help to get higher resolution than isotonic HPLC having constant peak width while in isotonic HPLC peak width increases with the retention time. Gradient HPLC has great sensitivity, especially for the products having longer retention time.

D. Column Size: 100-150 mm columns are used for most of the samples. It reduces the method development and analysis time for the sample. Bigger columns are used for complex samples those take more time in separation. Initially, a flow rate should be kept between 1 and 1.5 ml/min and column particle size should be between 3 and 5 μm.

E. HPLC Detectors: If the analyte has chromophores that enable the compound to be detected by UV than it is better to use UV detector. It is always better to use a UV detector than others. Fluorescence and electrochemical detectors should be used for trace analysis. Samples having high concentration should be analyzed using refractive index detectors.

F. Wavelength: λmax of the sample has the greatest sensitivity to the UV light. It detects the sample components that have chromophores. A wavelength above 200 nm gives greater sensitivity than the lower wavelengths. Wavelengths lower than 200 nm gives more noise, therefore, it should be avoided.

Related: Analytical Method Development Protocol

2. Selection of Chromatographic Conditions: After selection of analytical method, different chromatographic conditions are selected.

The flow of the analytes through the column depends upon the concentration of the solvent in the mobile phase. The concentration of solvent is generally used to control the retention time. Mobile phase pH and ion pairing reagents also affect the retention time of the sample. Samples having a large number of components are analyzed using the gradient to avoid the large retention time while the samples containing one or two components are analyzed on an isotonic system.

3. Parameter Optimization: After taking the same sample runs some parameters including column dimensions, particle size, run time and flow rate are optimized. It is done to get the best resolution and minimum run time. After proper optimization of the analysis method, it is validated to ensure the consistency of the analytical method. Analytical method validation is now done mandatory by all regulatory authorities.

Comments

Popular posts from this blog

Checklist for Audit in Sterile Area

Checklist for Audit in Sterile Area Checklist to verify the sterile manufacturing area before the audit. 1. Is there any SOP giving details for activity/ movement in the sterile area. 2. Verify the suitability of system for sanitization of hands. 3. Is there the SOP on entry-exit; gowning and de-gowning into the critical area available? 4. Verify the availability of following records:  Air pressure differential  Particulate monitoring  Temperature  Humidity  Microbiological monitoring by settle plate 5. Are these records available and maintained as per SOPs? 6. Check the above mentioned individual records. Are the entries within specifications mentioned in SOP/ MTPs. 7. Is the controlled copy of MTP pertaining to monitoring by settle plate available to plant person? 8. Are the location for settle plates identified and the chart/ layout available with plant? 9. Are the following areas monitored for parameters mentioned in step 4:  Air-lock to the critical ar...

Aseptic Filling Process (Media Fill) Validation Protocol in Sterile Pharmaceuticals

Aseptic Filling Process (Media Fill) Validation Protocol in Sterile Pharmaceuticals Validation of sterile manufacturing process by media fill validation test as per PICS guidelines for aseptic validation or aseptic process simulation. 1.0 OBJECTIVE 1.1 To define procedures for validating and maintaining the validation of all aseptic filling processes and qualification of the quality of the product by system/facility/equipment. 2.0 SCOPE 2.1 This procedure applies to all aseptically filled sterile products intended for human use. 3.0 RESPONSIBILITY 3.1 The Validation personnel coordinate the aseptic filling validation program and write the sterile media aseptic filling processes reports. 3.2 Manufacturing personnel the sterile media aseptic filling processes and performs the sterile media fills. 3.3 QA personnel perform the sampling and assist with the IPQA monitoring required for each sterile media fill. 3.4 QC personnel to perform the testing and assist with the monitoring required fo...

Blow Fill Seal (BFS) and Form Fill Seal (FFS) Technology in Sterile Manufacturing

Blow Fill Seal (BFS) and Form Fill Seal (FFS) Technology in Sterile Manufacturing Know about sterile pharmaceutical production using Blow Fill Seal (BFS) and Form Fill Seal (FFS) technology. Both of these techniques are used to manufacture  sterile pharmaceutical products   as parenteral (LVP & SVP), infusions, ophthalmic and inhalation products. These are automated techniques to prepare sterile products. The basic concept of the  FFS   and BFS is to reduce the  contamination   by forming the container, filling and sealing in a closed sterile chamber of the machine. There is no personnel intervention to reduce the chances of the contamination during the manufacturing of sterile products. It gives more production at very low operational cost with the high assurance of  sterility . Blow fill seal technology is widely used and accepted by the various pharmaceutical regulatory authorities as US-FDA and MHRA. The system is being used for over 30 years a...

MSDS (Material Safety Data Sheet)

MSDS   What Is an MSDS? An MSDS (Material Safety Data Sheet) is a document that provides detailed information about a chemical substance, including its hazards, safe handling procedures, storage requirements, and emergency measures. Today, MSDS is more commonly called SDS (Safety Data Sheet) under the Globally Harmonized System (GHS). Why MSDS / SDS Is Important Protect workers and employees Ensure safe handling and storage of chemicals Prevent accidents and injuries Provide emergency response information Comply with workplace safety regulations.  MSDS (Material Safety Data Sheet)  International safety standards.  GHS – Globally Harmonized System Full form: Globally Harmonized System of Classification and Labelling of Chemicals Develop by United Nations (UN).  OSHA (USA) – Hazard Communication Standard (HCS) Factories Act & Chemical Rules (India) Factories Act, 1948 Manufacture, Storage and Import of Hazardous Chemical Rules, 1989 REACH (Europe) REACH Regula...