Remove Residual Chlorine before Microbial Analysis

 
Remove Residual Chlorine before Microbial Analysis

It is important to remove the residual chlorine from the water sample before the microbial analysis.

Raw water is chlorinated by adding sodium hypochlorite (NaOCl) to make its concentration 2-4 ppm. Chlorination of water is done to remove the microbial load from the water. It helps the water system to produce the purified water of specified microbial quality.

Mechanism of Action:

When sodium hypochlorite is dissolved in water, it produces hypochlorous acid and hypochlorite ion. These hypochlorite ions are known as “free chlorine”. This free chlorine is responsible for the chlorination of the microbes in water. These ions are highly active and penetrate the cell wall via lipids and destroy the enzymes in the cells.

All the free chlorine is not consumed in the chlorination. This remaining chlorine is known as "residual chlorine" which can interfere with the microbial analysis of the water. This may alter the actual results.

Sodium thiosulfate (Na2S2O3) can be used to neutralize or remove residual chlorine. It simply reacts and forms sodium hydrogen sulfate or sodium bisulfate which is an inactive salt.

Na2S2O3 + 4HOCl + H2O -----> 2NaHSO4 + 4HCl

Add 0.1 ml of 10% solution of sodium thiosulfate is added to the water sample bottle before sterilization. This can be prepared by dissolving 100 gm of sodium thiosulfate crystals in about 500 ml of water making up a final volume to 1000 ml. This solution can be stored under refrigeration for six months.

This neutralization of residual chlorine will help to determine the actual microbial load in the water sample and will not affect the microbial recovery.

Comments

Popular posts from this blog

Checklist for Audit in Sterile Area

Checklist for Audit in Sterile Area Checklist to verify the sterile manufacturing area before the audit. 1. Is there any SOP giving details for activity/ movement in the sterile area. 2. Verify the suitability of system for sanitization of hands. 3. Is there the SOP on entry-exit; gowning and de-gowning into the critical area available? 4. Verify the availability of following records:  Air pressure differential  Particulate monitoring  Temperature  Humidity  Microbiological monitoring by settle plate 5. Are these records available and maintained as per SOPs? 6. Check the above mentioned individual records. Are the entries within specifications mentioned in SOP/ MTPs. 7. Is the controlled copy of MTP pertaining to monitoring by settle plate available to plant person? 8. Are the location for settle plates identified and the chart/ layout available with plant? 9. Are the following areas monitored for parameters mentioned in step 4:  Air-lock to the critical ar...

Aseptic Filling Process (Media Fill) Validation Protocol in Sterile Pharmaceuticals

Aseptic Filling Process (Media Fill) Validation Protocol in Sterile Pharmaceuticals Validation of sterile manufacturing process by media fill validation test as per PICS guidelines for aseptic validation or aseptic process simulation. 1.0 OBJECTIVE 1.1 To define procedures for validating and maintaining the validation of all aseptic filling processes and qualification of the quality of the product by system/facility/equipment. 2.0 SCOPE 2.1 This procedure applies to all aseptically filled sterile products intended for human use. 3.0 RESPONSIBILITY 3.1 The Validation personnel coordinate the aseptic filling validation program and write the sterile media aseptic filling processes reports. 3.2 Manufacturing personnel the sterile media aseptic filling processes and performs the sterile media fills. 3.3 QA personnel perform the sampling and assist with the IPQA monitoring required for each sterile media fill. 3.4 QC personnel to perform the testing and assist with the monitoring required fo...

Blow Fill Seal (BFS) and Form Fill Seal (FFS) Technology in Sterile Manufacturing

Blow Fill Seal (BFS) and Form Fill Seal (FFS) Technology in Sterile Manufacturing Know about sterile pharmaceutical production using Blow Fill Seal (BFS) and Form Fill Seal (FFS) technology. Both of these techniques are used to manufacture  sterile pharmaceutical products   as parenteral (LVP & SVP), infusions, ophthalmic and inhalation products. These are automated techniques to prepare sterile products. The basic concept of the  FFS   and BFS is to reduce the  contamination   by forming the container, filling and sealing in a closed sterile chamber of the machine. There is no personnel intervention to reduce the chances of the contamination during the manufacturing of sterile products. It gives more production at very low operational cost with the high assurance of  sterility . Blow fill seal technology is widely used and accepted by the various pharmaceutical regulatory authorities as US-FDA and MHRA. The system is being used for over 30 years a...