Preparation Process for Water for Injection (WFI) in Pharmaceuticals

 
Preparation Process for Water for Injection (WFI) in Pharmaceuticals

Water for injection is used in sterile manufacturing and its preparation and storage is a critical process.

There are basically two types of water preparation in pharmaceuticals. Water for Injection (WFI) preparation process and purified water preparation process. The analytical standards for the two water are almost very similar, the only difference is that Water for Injection (WFI) system in pharmaceuticals has stricter bacterial control standards than USP standards for purified water process and has to pass the bacterial endotoxin test.

Preparation methods are very similar to a particular point, however, Water for Injection (WFI) preparation process in pharmaceuticals must include distillation or double pass reverse osmosis techniques.

Dechlorination: This refers to the removal of chlorine from the water. There are several ways of dechlorination.This include injection of a reducing agent like sodium metabisulfite and exposure to a high dosage of UV rays can dechlorinate. However, the most common one is filtration through activated carbon media.

Water for Injection (WFI) preparation process in pharmaceuticals is dechlorinated by carbon. Carbon dechlorinates by chemically reacting with the free chlorine in water to form hydrochloric acid and carbon monoxide or dioxide. High doses of UV light rays are widely used in water purification systems for both disinfection and TOC reduction. Another use of UV is dechlorination though it is a relatively new process.

Ion removal: There are basically three types of ion reduction processes these include membrane processes, ion exchange processes, and distillation processes. Membranes are used in water purification systems to remove ions, remove particulate, remove organic compounds, and remove living organisms. Membranes are different from one another in terms of pore size, molecular weight, and even on ion rejection.

Ion removal membranes include membranes such as reverse osmosis membranes and nanofiltration membranes. These are used in ion reduction processes. The ion exchange systems provide additional ion reduction process, making the water much lower in conductivity than required and it also provides a back up for membrane process. Distillation can also be used to remove ion, however, it is very expensive.

Bacterial control: In bacteria control, one has to be careful to ensure that bacteria does not pass to pharmaceutical water for injection. Bacteria control includes both procedures and equipment. Equipment utilized are ultraviolet (UV) lights, ozone generation systems for production of ozone, heating systems for thermal treatment, and chemical injection and recirculation systems. Procedures in this process include periodic sanitizations and also general operational techniques to avoid intrusion of bacteria.

Bacterial control is usually applied during processing, storage and even distribution. UV light is an excellent non-chemical method of disinfecting Water for Injection (WFI). Thermal sanitization involves the use of heat to kill the bacteria. Ozone can also be used since it is a very strong oxidizing agent it can, therefore, oxidize bacteria. Chemicals can also be used to kill bacteria as a means of bacteria control.

Removal of specific impurities: There are various different sources of water for Injection (WFI) used during preparation process in pharmaceuticals. Every source is different and therefore the possibilities of specific contaminant problem are possible. These contaminants include Iron, manganese, hydrogen sulfide, hardness ions, particulate matter, high conductivity. Filtration can be used to remove any heavy loads. Cartridge filters are also used to remove essentially any sized particles. However, they are expensive.

The last stage is storage. Care and hygiene must be maintained during storage of WFI. Bacteria control must also be incorporated at this stage.

Comments

Popular posts from this blog

Sterility Testing by Direct Inoculation Method

Sterility Testing by Direct Inoculation Method Direct Inoculation Method Learn the procedure for sterility test for sterile pharmaceutical products by direct inoculation method. 1.0 Objective :  To lay down Standard Operating Procedure is to provide guidelines for sterility testing by Direct Inoculation Method. 2.0 Scope This procedure is applicable for the products manufactured at the location which can not be tested by Membrane Filtration Method. 3.0 Responsibility Implementation: Microbiologist 4.0 Accountability Execution: Manager - QC Review & Approval : AGM - QA / QC Procedure Direct Inoculation Method Sample for Finished Products: Collect the samples to be tested for sterility. Out of the whole sample, randomly select 20 articles of each lot of batch for both LVP and SVP t erminal ly sterilized products and for aseptically filled products.    Sample for Intermediates: Randomly collect 16 pre-sterilized bottle samples to be tested for sterility from LVP bot...

SOP for Washing of HPLC Column After Use

SOP for Washing of HPLC Column After Use Standard operating procedure to wash the HPLC column after analysis. 1.0 OBJECTIVE To clean the column thoroughly after its each use to avoid any interference on repeated usage. 2.0 SCOPE This procedure is applicable for different groups of H.P.L.C columns used in Quality Control laboratory. 3.0 RESPONSIBILITY 2.1 Doing: Technical Assistant 2.2 Checking: Executive /Manager 4.0 ACCOUNTABILITY Head of the Department 5.0 PROCEDURE 5.1 For C18, C8, C6, Phenyl, (CN, Amine, Silica column.:) 5.1.1 Wash the column with the solvent which is use in individual product mobile phase preparation. eg. suppose water is use in mobile phase  preparation then wash the column with water. 5.1.2 Allow the minimum 30 ml washing medium to flow through the column. 5.1.3 Disconnect the column from the HPLC unit and store in an allocated place. 5.2 For Protein pack column: 5.2.1 Wash the column with minimum 30 ml of 2.5 M acetic acid. 5.2.4 Disconnect the column from ...

Blow Fill Seal (BFS) and Form Fill Seal (FFS) Technology in Sterile Manufacturing

Blow Fill Seal (BFS) and Form Fill Seal (FFS) Technology in Sterile Manufacturing Know about sterile pharmaceutical production using Blow Fill Seal (BFS) and Form Fill Seal (FFS) technology. Both of these techniques are used to manufacture  sterile pharmaceutical products   as parenteral (LVP & SVP), infusions, ophthalmic and inhalation products. These are automated techniques to prepare sterile products. The basic concept of the  FFS   and BFS is to reduce the  contamination   by forming the container, filling and sealing in a closed sterile chamber of the machine. There is no personnel intervention to reduce the chances of the contamination during the manufacturing of sterile products. It gives more production at very low operational cost with the high assurance of  sterility . Blow fill seal technology is widely used and accepted by the various pharmaceutical regulatory authorities as US-FDA and MHRA. The system is being used for over 30 years a...

Aseptic Filling Process (Media Fill) Validation Protocol in Sterile Pharmaceuticals

Aseptic Filling Process (Media Fill) Validation Protocol in Sterile Pharmaceuticals Validation of sterile manufacturing process by media fill validation test as per PICS guidelines for aseptic validation or aseptic process simulation. 1.0 OBJECTIVE 1.1 To define procedures for validating and maintaining the validation of all aseptic filling processes and qualification of the quality of the product by system/facility/equipment. 2.0 SCOPE 2.1 This procedure applies to all aseptically filled sterile products intended for human use. 3.0 RESPONSIBILITY 3.1 The Validation personnel coordinate the aseptic filling validation program and write the sterile media aseptic filling processes reports. 3.2 Manufacturing personnel the sterile media aseptic filling processes and performs the sterile media fills. 3.3 QA personnel perform the sampling and assist with the IPQA monitoring required for each sterile media fill. 3.4 QC personnel to perform the testing and assist with the monitoring required fo...

Media Fill Test for Sterile API Manufacturing Process

Media Fill Test for Sterile API Manufacturing Process Know about the process simulation test for the active pharmaceutical ingredient (API) manufacturing process. Media fill test is done to verify the sterility of the sterile manufacturing process. Media fill validation for sterile API is different from the sterile formulation media fill. There are different processes in the sterile API manufacturing as filtration, crystallization, drying, milling etc. These all are different from the sterile formulation process where the sterile material is filled in sterile containers in aseptic conditions . Lactose powder is used in the process simulation. The whole media fill process is carried out in two phases 1) Wet Phase  2) Dry phase 1) Wet Phase:   Non-sterile lactose powder is used in the wet phase. Wet phase simulates the liquid processing steps of the manufacturing process  i.e. aseptic filtration of lactose solution from controlled area reactor to cryst...