System Suitability in HPLC Analysis

System Suitability in HPLC Analysis

System suitability is to prove that system is working perfectly before the analysis on HPLC, GC, TOC analyzer or any other system. It is required to done before every 

sample analysis.

HPLC, short for High-performance liquid chromatography is a technique used for separating the components in a mixture. In the HPLC technique, a liquid sample is passed over an absorbent material to test its efficacy.

HPLC chromatography technique is used in pharmaceutical industries for research and testing purposes. Most of the pharmaceutical companies follow a three-step approach to check the functioning of their High performance liquid chromatography systems- Initial System Qualification, Method Validation and Suitability Testing (SST).

System Suitability Test (SST)

Selecting a proper System Suitability Testing mixture is essential to check the specifications of a liquid chromatographic system. System Suitability Testing limits are acceptance criteria that must be met prior to sample analysis. Some of the common chromatographic systems used in pharmaceutical sample analyses are:

  • Active ingredient assays
  • Impurity determinations
  • Dissolution testing

The System Suitability Testing limits should conform to the guidelines provided by CDER (Center for Drug Evaluation and Research). Other sources for referencing about the System Suitability Testing are the USP (United States Pharmacopeia) and the ICH (The International Conference on Harmonization of Technical Requirements for Registration of Pharmaceuticals for Human Use). Especially, one of the ICH’s guidelines has a section dealing entirely with the System Suitability Testing. Some parameters which can be checked using the System Suitability Testing are:Resolution

  • Retention time
  • Pressure
  • Column efficiency
  • Repeatability
  • Plate Number
  • Tailing factor
  • Signal-to-noise ratio

Let us look at some of these parameters.

Resolution: One of the most important parameters. Resolution is used to check whether the critical separation is feasible under the given conditions.

Retention time: Retention time is one of the easy-to-identify parameters. The resolution should be fairly constant. This is because values outside the retention-time window might go unreported by the system under test.

Pressure: The suitability testing must be carried out within set pressure limits. This is to ensure that wearing of system components is reduced.

The column is efficiency-Also known as band broadening.

Repeatability: Successive measurements taken under the same measurement conditions should give the same results.

Plate number: The Plate number is a theoretical plate index(N) used to determine column efficiency. The plate number is arrived at by using the plate theory. Plate number changes depending on the type of analysis carried out.

Tailing factor: This is also called as Symmetry factor. Tailing factor becomes important if the peak tailing has chances of affecting the method’s performance. Similar to Plate number, the Tailing factor also depends upon the type of analysis.

Signal-to-Noise Ratio: S/N ratio is a measure of the system’s performance at the lower end.It is not enough to perform System Suitability Testing at the beginning of the assay alone. For the purpose of periodic monitoring, it is necessary to do the System Suitability Testing at regular intervals. This is because the performance of the system under test may change due to continuous use.

Summary

The System Suitability Tests mentioned in this article are not exhaustive. The System Suitability Tests to be performed are decided by the pharmaceutical scientists or analysts, considering various factors of the system under test. Pharmaceutical scientists use statistical analyses to set realistic System Suitability Testing limits. An optimum system should provide the maximum information out of a minimum number of tests. The System Suitability Tests should be designed such that the requirements are met easily when the system is functioning correctly and fails if there is a problem.

Comments

Popular posts from this blog

Checklist for Audit in Sterile Area

Checklist for Audit in Sterile Area Checklist to verify the sterile manufacturing area before the audit. 1. Is there any SOP giving details for activity/ movement in the sterile area. 2. Verify the suitability of system for sanitization of hands. 3. Is there the SOP on entry-exit; gowning and de-gowning into the critical area available? 4. Verify the availability of following records:  Air pressure differential  Particulate monitoring  Temperature  Humidity  Microbiological monitoring by settle plate 5. Are these records available and maintained as per SOPs? 6. Check the above mentioned individual records. Are the entries within specifications mentioned in SOP/ MTPs. 7. Is the controlled copy of MTP pertaining to monitoring by settle plate available to plant person? 8. Are the location for settle plates identified and the chart/ layout available with plant? 9. Are the following areas monitored for parameters mentioned in step 4:  Air-lock to the critical ar...

Aseptic Filling Process (Media Fill) Validation Protocol in Sterile Pharmaceuticals

Aseptic Filling Process (Media Fill) Validation Protocol in Sterile Pharmaceuticals Validation of sterile manufacturing process by media fill validation test as per PICS guidelines for aseptic validation or aseptic process simulation. 1.0 OBJECTIVE 1.1 To define procedures for validating and maintaining the validation of all aseptic filling processes and qualification of the quality of the product by system/facility/equipment. 2.0 SCOPE 2.1 This procedure applies to all aseptically filled sterile products intended for human use. 3.0 RESPONSIBILITY 3.1 The Validation personnel coordinate the aseptic filling validation program and write the sterile media aseptic filling processes reports. 3.2 Manufacturing personnel the sterile media aseptic filling processes and performs the sterile media fills. 3.3 QA personnel perform the sampling and assist with the IPQA monitoring required for each sterile media fill. 3.4 QC personnel to perform the testing and assist with the monitoring required fo...

Blow Fill Seal (BFS) and Form Fill Seal (FFS) Technology in Sterile Manufacturing

Blow Fill Seal (BFS) and Form Fill Seal (FFS) Technology in Sterile Manufacturing Know about sterile pharmaceutical production using Blow Fill Seal (BFS) and Form Fill Seal (FFS) technology. Both of these techniques are used to manufacture  sterile pharmaceutical products   as parenteral (LVP & SVP), infusions, ophthalmic and inhalation products. These are automated techniques to prepare sterile products. The basic concept of the  FFS   and BFS is to reduce the  contamination   by forming the container, filling and sealing in a closed sterile chamber of the machine. There is no personnel intervention to reduce the chances of the contamination during the manufacturing of sterile products. It gives more production at very low operational cost with the high assurance of  sterility . Blow fill seal technology is widely used and accepted by the various pharmaceutical regulatory authorities as US-FDA and MHRA. The system is being used for over 30 years a...